Integrated programme

From China to Europe: one programme, founder-led coordination.

Kaiveo Medical offers founder-led support across regulatory, clinical, quality and medical evidence planning, with deliverables agreed for each engagement. Quality readiness and payer evidence are considered from assessment through lifecycle planning. Language support is agreed for each engagement.

Programme stages5
Disciplines integrated4
Programme leadFounder-led
Programme scheduleAgreed by scope
Why Europe

A market worth the effort, for those who prepare.

European entry depends on product-specific evidence, documentation and quality readiness. Regulatory authorisation and national pricing, reimbursement and adoption are separate decisions.

One framework, many markets

EU medicines procedures and device conformity routes support entry across the EU and EEA, subject to product-specific obligations. National health systems make separate pricing, reimbursement and adoption decisions.

Global credibility

An EU marketing authorisation, relevant GMP evidence or CE marking can inform discussions in other regions; each authority and commercial counterparty makes its own assessment.

Structured regulatory pathways

Defined procedures and scientific dialogue help frame evidence planning. Review clocks exclude preparation and may be extended by questions or additional evidence needs.

The programme

Five stages from first assessment to European growth.

Each stage has agreed deliverables and a decision gate. Quality readiness and market-access evidence run across all five stages; scope, responsibilities and schedule are confirmed before work starts.

01

Assess: strategy & feasibility

Scope agreed

We assess target indications, priority countries, regulatory options and gaps in existing data, manufacturing and quality readiness. Early pricing, reimbursement and payer-evidence questions inform comparator and endpoint choices. The agreed output is a sequenced plan with budget assumptions, responsibilities and risks.

Deliverables

  • Market, competitor & payer-evidence needs
  • Regulatory gap analysis
  • Country prioritisation
  • Integrated budget, timeline & risk register
02

Prepare: regulatory pathway

Schedule agreed

For medicines, we assess mandatory or optional centralised eligibility and national-authority routes: decentralised, mutual recognition or national. Biotechnological medicines, including relevant biosimilars, may fall within mandatory centralised scope. Drug-led combination products typically follow the medicines route, with device-component assessment as applicable. For devices and IVDs, classification and conformity requirements are assessed separately. Advice requests and gap-closure work are scoped to the evidence need.

Deliverables

  • Regulatory strategy & procedure selection
  • Agency / notified-body briefing packages
  • Dossier or technical documentation gap closure
  • Submission plan & interaction calendar

Workstreams in scope

03

Prove: clinical development

Schedule agreed

We assess existing data for quality, relevance and fit to the intended population, claims and regulatory route. Clinical support covers study design, country and site options, budget, CRO selection and ethics coordination. Regulatory leads CTA and CTIS coordination for medicines under the CTR; device investigations and IVD performance studies follow separate MDR and IVDR requirements. Any oversight work and payer-relevant endpoints are agreed in scope.

Deliverables

  • Clinical evidence & study-design plan
  • Regulatory-led CTA / CTIS coordination
  • CRO / vendor selection & scoped oversight
  • Clinical data package for submission

Workstreams in scope

04

Comply: quality & compliance

Schedule agreed

Quality readiness starts in Assess and continues through development, submission and lifecycle work. We review QMS, site and supplier gaps and support agreed remediation and audit preparation. Requirements for QP, QPPV, EU Authorised Representative, PRRC and trial legal representation depend on the product and activity. Statutory appointments require appropriately qualified providers; appointment, import and release responsibilities must be agreed separately.

Deliverables

  • QMS gap assessment & remediation planning
  • Mock inspections / audits & CAPA
  • Supplier & CDMO qualification review
  • EU role & supply-chain requirements

Workstreams in scope

05

Launch & grow: evidence & lifecycle

Ongoing

Following the relevant regulatory decision, scoped support may cover medical evidence planning, lifecycle submissions and review of post-market obligations. Pricing, reimbursement and adoption remain separate from authorisation or CE marking. The sponsor or manufacturer retains its legal responsibilities; safety-system operation and statutory roles require qualified providers and explicit scope.

Deliverables

  • Medical evidence & launch-readiness plan
  • Evidence gaps for access & adoption
  • PMS / PV obligations & responsibilities review
  • Lifecycle & expansion roadmap

Workstreams in scope

The European landscape

The frameworks your programme will navigate.

A high-level map. Every engagement starts by identifying exactly which of these apply to your product.

Medicinal products

EMA / CHMP assessment and European Commission authorisation under the centralised procedure; national competent authorities manage decentralised, mutual-recognition and national routes. Orphan designation, PRIME eligibility and paediatric investigation plans are distinct requirements or programmes.

Medical devices & IVDs

MDR 2017/745 for devices and IVDR 2017/746 for IVDs, with separate classification rules, class-dependent notified-body involvement, CE marking and applicable UDI / EUDAMED obligations.

Clinical trials

Medicines trials follow the Clinical Trials Regulation 536/2014 through CTIS. Device clinical investigations follow the MDR; IVD performance studies follow the IVDR. The applicable standards, ethics and country requirements must be identified for each study.

Manufacturing & distribution

EU GMP and GDP, Qualified Person batch release, importation requirements and ISO 13485 for device manufacturers.

Post-market obligations

Pharmacovigilance and the QPPV role, PSURs, post-market surveillance, PMCF and vigilance reporting for devices.

Access & adoption

EU HTA joint clinical assessments, national pricing and reimbursement systems, and the medical evidence that supports them.

Pathways

Which European route, and what it asks for.

Medicines require marketing authorisation; devices and IVDs require the applicable conformity assessment and CE marking. Drug-led combination products typically follow the medicines route with device-component assessment as applicable.

European medicines, device and IVD routes; drug-led combinations typically follow the medicines route What is it? Product and lead action MEDICINES / DRUG-LED In mandatory centralised scope? EMA / CHMP assessment Commission authorisation DCP / MRP / national national authority decisions DEVICES AND IVDs Classify under MDR or IVDR rules MDR I / IVDR A* self-declaration where eligible Other classes / exceptions* notified-body assessment Before you ship MAH or authorised representative in the EU Medicines: QP release Devices: UDI / registration
Drug-led combinations typically use the medicines route, with device-component assessment as applicable. *MDR devices use classes I, IIa, IIb and III; IVDR IVDs use A, B, C and D. Eligible MDR class I and non-sterile IVDR class A products may be self-declared. MDR class Is, Im and Ir and sterile IVDR class A require notified-body involvement for specified aspects; other classes generally require notified-body assessment. Medicines and devices have different EU-established role, release and registration obligations.
The European clocks, and what is not counted in them.
RouteWhat it isThe clockWhat stops it
CentralisedOne authorisation valid across the Union210 active days at CHMP, then a Commission decisionClock-stops while you answer the lists of questions
DecentralisedSimultaneous application in the countries you selectStandard timetable to Day 210, then roughly 30 days nationallyApplicant response periods, unresolved objections and possible referrals; national translations follow
Mutual recognitionRecognition of an existing national authorisationA recognition phase of 90 daysObjections on grounds of potential serious risk to public health
Clinical trialAuthorisation under the Clinical Trials Regulation, through CTISNormally 45 days for assessment from validation, followed by country decisionsValidation time, RFIs and applicable expert-consultation extensions; each country issues its decision after Part I and II conclusions
Notified bodyClass-dependent assessment under MDR or IVDRNo single statutory end-to-end clock; body capacity and scope matterNonconformities, and the time to close them

Quality readiness runs from assessment onward: EU GMP, relevant importation controls and QP certification for medicines; applicable MDR / IVDR QMS requirements for devices and IVDs. Inspection needs depend on the site, activity and regulatory assessment. The medicines CTA assessment clock above starts at validation, not project start; see the EMA CTIS Sponsor Handbook for RFI, decision and calendar rules.

Interactive readiness check

How ready are you for Europe?

Switch on each statement that is true for your organisation today. The indicator suggests where your programme should start. Illustrative only, not a formal assessment.

0%readiness

Early exploration

You are at the very start. A structured feasibility assessment will clarify your regulatory route, budget and timeline before any commitments are made.

Discuss your result
Questions we hear most

Frequently asked about entering Europe.

Do we need a European legal entity before we start?
Not necessarily at the start. Several roles can be fulfilled by representatives, and the right corporate structure depends on your commercial model. We help you decide what is needed and when.
Which European country should we enter first?
It depends on the product, the reimbursement environment, reference-pricing effects and your commercial partners. Country sequencing is a core output of the Assess stage.
Can we run the programme with our existing global CRO or consultants?
Yes. Kaiveo Medical can provide founder-led coordination or a defined workstream alongside your existing CRO or consultants. Deliverables, responsibilities and oversight boundaries are agreed for each engagement.
What do you need from us to give a first opinion?
Start with a brief product summary, development stage and target European markets. Please ask about confidentiality arrangements before sharing non-public documents.
Europe Market Entry

Start with a feasibility conversation.

No commitment, no jargon, just an honest view of your pathway to Europe.

We aim to reply within two working days. Language support is agreed for each engagement.